send message order online
+372 62 28 220 call us for best offer
Home » Relays and monitoring devices » Dold safety devices » Multifunctional safety solutions

DOLD Multifunctional safety solutions: SAFEMASTER C

send
Multifunctional safety solutions: SAFEMASTER C
Whether it is used as an individual device or integrated in complex safety systems - with SAFEMASTER C, you always have the right solution for protecting people and machinery. With the compact multifunctional safety switching devices from DOLD, various safety-oriented inputs, such as emergency stop, safety door, et cetera, are assigned to a single output. An additional important advantage of SAFEMASTER C is the cost-savings as a result of its multi-functionality: through taking up less space in the control cabinet than mono-functional safety devices, through reduced storage needs and through the simple and fast calibration of the safety functions and operating modes.
order
Type Function Application Cat. / PL acc. to EN 13894-1 1) SIL CL acc. to EN 62061 1) Safe output contacts, redundant NO contacts max. Auxiliary contacts, NC contacts max. Feedback for ext.  monitoring Width [mm]
Emergency-stop Light curtain Safety gate Two-hand Safety mat
UG 6970 Multifunctional  safety module + 2) + 2) + 2) IIIC 2) + 2) 4 / e 3 4

22.5
UG 6980 Multifunctional  safety module + + + IIIC + 4 / e 3 2

22.5
UG 6960 Multifunctional safety timer with instantaneous contacts 3) 3) 3) IIIC 3) 3) 4 / e 3 4

22.5
UG 6961 Multifunctional  safety timer 3) 3) 3) IIIC 3) 3) 4 / e 3 2

22.5
BH 59 Multifunctional  safety module + + + IIIC, IIIA) + 4 / e 3 3 1 + 45
1) Please check state of approval of idividual devices in the latest data sheet.
2) Adjustable two of five functions
3) Optionally available
Following product are also available: BH 5910/02MF2
For more complex applications see SAFEMASTER M

DOLD Multifunctional safety solutions SAFEMASTER M
Multifunktional safety solutions SAFEMASTER M
The modular safety system SAFEMASTER M is an optimal solution for many areas of machinery and system construction. The safety functions can be adjusted the respective requirements cost-effectively with software-free device configuration. SAFEMASTER M essentially consists of four modules: the control unit as well as the input, output and diagnosis module. The input module with freely selectable safety functions can be assigned to various output modules. The optional field bus connection allows the visualization of the system status. The result is increased system availability.
order
Type Function Application Category acc. to EN 13849-1 Type EN 574 Safe output contact Auxiliary Width [mm]
Emergency-stop Light curtain Safety gate Two-
hand
Start Stopp Redundant NO contacts Time delay NC contact Feedback for ext. monitoring
BH 5911.03 Control unit + +

4 1 4
3 3
+ 45
BH 5911.22 Control unit + +

4 1 4
2 2 1 + 45
BG 5913.08/0 Input module + + + +

4 IIIA,
IIIC




22.5
BH 5913.08/0 Input module with
isolated inputs
+ + + +

4 IIIA,
IIIC




45
BG 5913.08/1 Input module + + + +

4 IIIC



22.5
BG 5913.08/12 Input module + + + +

4 IIIC



22.5
BG 5913.08/3 Input module + +
+

4 IIIC



22.5
BG 5914.08/0 Input module + +



4




22.5
BH 5914.08/0 Input module with
isolated inputs
+ +



4




45
BG 5915.08/1 Input module with
monitoring function
+
+


4




22.5
BH 5915.08/1 Input module with
monitoring function
and isolated inputs
+
+


4
4

+ 45
BG 5912.04 Output module







3
1 + 22.5
BG 5912.48 Output module








3
+ 22.5
BG 5912.86 Output module








2 1 + 22.5
BG 5912.95 Output module











22.5
BG 5551 Diagnostic Module 
for CANopen












22.5
BH 5552 Diagnostic Module for Profibus DP











45

DOLD Configurable Safety System SAFEMASTER PRO
Configurable Safety System SAFEMASTER PRO
The modular and configurable safety system SAFEMASTER PRO monitors all safety circuits of you machinery and installations – in a simple, flexible and safe way. The DOLD safety system consists of a control unit and up to 14 expansion modules. Pure input, pure output and combined input/output modules are available for the simple adjustment to the respective task. SAFEMASTER PRO is suitable for safety applications up to PL e / cat. 4 and SIL 3; its hardware and software are TÜV-certified. You can configure the system with SAFEMASTER PRO Designer. The projection takes place easily per drag & drop via the graphic configuration software.
order
Type Function Application Cat. / PL acc. to EN 13894-1 1) SIL CL acc. to EN 62061 1) Safety inputs max. Safety NO contacts max. NC contacts max. Safety, 2-channal outputs OSSD max. Test outputs for  sensor monitoring max. Feed- back  for ext. moni- toring Width [mm]
Emer- gency- stop 2) Light curtain 2) Safety gate 2) Two-han d 2) Safety mat 2)
UG 6911.10 Control unit + + + + + 4 / e 3 8

2 4 2 22.5
UG 6913 Input module + + + + + 4 / e 3 16


8
22.5
UG 6912.02 Output module ossd




4 / e 3


4
4 22.5
UG 6912.14
UG 6912.28
Output module Relay extension




4 / e 3
4 2


22.5
UG 6916.10 Input / Output module + + + + + 4 / e 3 8

2 4 2 22.5
UG 6918 Bus Extender
+


4 / e 3





22.5
UG 6951,
UG 6952,
UG 6954
Fieldbus module
+


4 / e 3





22.5
1) Please check state of approval of idividual devices in the latest data sheet.
2) More configurable security features, refer to the brochure and in the manual SAFEMASTER PRO

Technical Information and Features

DOLD Safemaster M system overview.

With the multi-functional safety system SAFEMASTER M and its simple assembly, you are equipped for your safety applications in machine and equipment manufacturing. The central control unit, which is equipped with safety inputs and safety output with 3 contact paths can be flexibly expanded depending on use with up to three input modules (to the left of the control unit) and up to three output modules (to the right of the control unit) via a ribbon cable. Thus the SAFEMASTER M is the optimal solution for scalable machines and equipment, for example for the paper and printing industry, molding technology, the packaging industry or the recycling industry, and can be adapted to future requirements. The SAFEMASTER M safety system can be connected to the existing automation solution using an optional field bus module. System status is visualized and enables an easy diagnosis.

Minimal configuration:
The control unit is the entry point of the SAFEMASTER M system. This unit alone can monitor 2 emergency off buttons (1 channel) or 1 emergency off button and a touchless protective unit (2 channel) 3 safety-oriented contact paths and 2 semiconductor monitoring outputs are also available.
Maximum configuration:
SAFEMASTER M is an expandable, scalable and multi-functional safety system. In the maximum configuration it includes the control unit, 3 input and 3 output modules as well as a field bus module. Thus the system offers up to 26 inputs for emergency off buttons, light grids, safety doors or two hand buttons and up to 15 safety-oriented contact paths.

Your safety is simply configured in 3 steps with Dold Safemaster M.

Configure the TÜV certified SAFEMASTER M safety system quickly and easily using DIP and rotary switches and adapt your SAFEMASTER M to your safety application. The individual units of the SAFEMASTER M system are connected to each other with ribbon cables. Additional inputs are powered by the control unit via the ribbon cable, reducing hard wiring expenses. SAFEMASTER M is flexibly adapted to your requirements by adding input and output modules. The modularity concept is further reinforced by the multi-functionality of the input modules. The inputs are assigned to the desired functions via rotary switch for a spectrum of safety functions.The assignment of inputs to outputs as well as the links to up to 4 start buttons is done most easily by DIP switch on the relevant input module. Every input module can also act on one or more output expansions or even on the outputs of the control unit. Thus groups or hierarchies can be formed flexibly, completely without software.
Your safety is simply configured in 3 steps with Dold Safemaster M.

DOLD Safemaster M - forming groups and hierarchies

Multifunctional and easy to adjust.
With SAFEMASTER M, you can easily and simply configure the safety infrastructure of your system. Using the DIP switch you can determine which actors are served by the connected safety sensors and which are not. The inputs can be flexibly assigned to the outputs of the central control unit and/or to one to three output expansions, whatever your application requires.

Individual safety solution made-to-measure.
SAFEMASTER M can form groups and hierarchies within your facility, which make your process not only safer, but also more efficient. SAFEMASTER M performs the function of a small safety PLC. Through “switch programming”, not only are the inputs assigned to the outputs, but also up to 4 start switches are assigned to the safety functions, all without software. On the output side too, the multifunctional SAFEMASTER M system offers the highest degree of flexibility. In addition to designs with up to 4 safety oriented contact paths, there are also release delayed output expansions available with delay times of up to 20 seconds. SAFEMASTER M is thus perfectly adapted to your safety solution.

Configure your system individually in zones with DOLD Safemaster.

An industrial system typically consists of multiple units or zones. If an emergency situation occurs or a safety function is triggered, the entire system may be affected – or only individual safety zones. The complete system does not always have to be shut down. SAFEMASTER M offers an efficient solution to this with flexible assignment of inputs to outputs, even without the use of complex programmable systems. In addition, SAFEMASTER M can be optimally combined with the SAFEMASTER STS safety switch and key transfer system. Maintenance and safety doors of separating protective equipment are secured with the switches and solenoid guard locks of the SAFEMASTER STS system, while the monitoring of light barriers and emergency off switches is done by SAFEMASTER M.