send message order online
+372 62 28 220 call us for best offer

DOLD MULTIFUNCTIONAL SAFETY MODULE UG 6980

send

The multifunctional safety module UG 6980 provides protection of men and machines by enabling and disabling a safety circuit. It is used together with e-stop buttons, safety gates, light curtains with self testing (type 4) to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and productions machines with dangerous closing movements (type III C to EN ISO 13851) and safety mats, edges and tape switches. Simply select 1 out of 6 safety functions on rotary switches - ready. This reduces divers types of safety modules in stock and simplifies your disposition.

Applications

Protection of people and machines
  • Emergency stop circuits on machines
  • Monitoring of position switches on a safety gate
  • Switch gear (FSD) for light bars with selftest (type 4) according to IEC/EN 61496-1
  • 2-hand controls for presses as well as other production machinery with dangerous closing action (Type III C to EN ISO 13851)
  • Switch gear for safety mats, safety edges and tape switches with a max. switching current of 15 mA.

Downloads

Datasheet UG 6980


MODEL RANGE
Order Code Model Description Sales Price
0065427 UG6980.02PS/61 DC24V MULTIFUNCTIONAL SAFETY MODULE € 260,00
0066927 UG6980.04PC/61 DC24V MULTIFUNCTIONAL SAFETY MODULE € 398,00
0066366 UG6980.04PS/61 DC24V MULTIFUNCTIONAL SAFETY MODULE € 391,00
Technical Information and Features

Advantages

  • Adjustable safety functions:
    - E-Stop
    - Safety gate
    - Two-hand control
    - Safety mat / Safety edge
    - Exclusive or contacts
    - Light curtain
  • Manual or auto start
  • Only one device, different safety functions
  • Protection against manipulation by sealable transparent cover

Features

  • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • Acc. to EN 50156-1 for furnaces
  • Line fault detection on On-button:
  • Manual restart or automatic restart
  • With or without cross fault monitoring
  • 2-channel
  • Forcibly guided output contacts
  • Output: max. 4 NO instantaneous semiconductor monitoring output
  • LED indicator for operation, delay contects and failure
  • As option with pluggable terminal blocks for easy exchange of devices
    - with screw terminals
    - or with cage clamp terminals
  • Width: 22.5 mm