DOLD MULTIFUNCTIONAL SAFETY MODULE UG 6980
The multifunctional safety module UG 6980 provides protection of men and machines by enabling and disabling a safety circuit. It is used together with e-stop buttons, safety gates, light curtains with self testing (type 4) to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and productions machines with dangerous closing movements (type III C to EN ISO 13851) and safety mats, edges and tape switches. Simply select 1 out of 6 safety functions on rotary switches - ready. This reduces divers types of safety modules in stock and simplifies your disposition.
Applications
Protection of people and machines- Emergency stop circuits on machines
- Monitoring of position switches on a safety gate
- Switch gear (FSD) for light bars with selftest (type 4) according to IEC/EN 61496-1
- 2-hand controls for presses as well as other production machinery with dangerous closing action (Type III C to EN ISO 13851)
- Switch gear for safety mats, safety edges and tape switches with a max. switching current of 15 mA.
Downloads
MODEL RANGE
Order Code | Model | Description | Sales Price | |
---|---|---|---|---|
0065427 | UG6980.02PS/61 DC24V | MULTIFUNCTIONAL SAFETY MODULE | € 260,00 | |
0066927 | UG6980.04PC/61 DC24V | MULTIFUNCTIONAL SAFETY MODULE | € 398,00 | |
0066366 | UG6980.04PS/61 DC24V | MULTIFUNCTIONAL SAFETY MODULE | € 391,00 |
Technical Information and Features
Advantages
- Adjustable safety functions:
- E-Stop
- Safety gate
- Two-hand control
- Safety mat / Safety edge
- Exclusive or contacts
- Light curtain - Manual or auto start
- Only one device, different safety functions
- Protection against manipulation by sealable transparent cover
Features
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 - Acc. to EN 50156-1 for furnaces
- Line fault detection on On-button:
- Manual restart or automatic restart
- With or without cross fault monitoring
- 2-channel
- Forcibly guided output contacts
- Output: max. 4 NO instantaneous semiconductor monitoring output
- LED indicator for operation, delay contects and failure
- As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals - Width: 22.5 mm