MULTIFUNCTIONAL SAFETY MODULE UG6980.04PC/61 DC24V (0066927)
The multifunctional safety module UG 6980 provides protection of men and machines by enabling and disabling a safety circuit. It is used together with e-stop buttons, safety gates, light curtains with self testing (type 4) to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and productions machines with dangerous closing movements (type III C to EN ISO 13851) and safety mats, edges and tape switches. Simply select 1 out of 6 safety functions on rotary switches - ready. This reduces divers types of safety modules in stock and simplifies your disposition.
Applications
Protection of people and machines- Emergency stop circuits on machines
- Monitoring of position switches on a safety gate
- Switch gear (FSD) for light bars with selftest (type 4) according to IEC/EN 61496-1
- 2-hand controls for presses as well as other production machinery with dangerous closing action (Type III C to EN ISO 13851)
- Switch gear for safety mats, safety edges and tape switches with a max. switching current of 15 mA.
Downloads
Technical specifications
Manufacturer: | Dold |
Series: | UG 6980 |
Type: | UG6980.04PC/61 DC24V |
Article number: | 0066927 |
Sales Price: | € 398,00 |
|
|
Contacts: | 4 NO contacts |
Nominal voltage: | DC 24 V |
Terminal type: | Pluggable terminal blocks with cage clamp terminals |
Approvals and Markings: | UL-listed C/US, TÜV, UKCA |
Variant: | Safety functions adjustable |
Common technical specifications UG 6980 | |
Width: | 22,5 mm |
Cat. / PL acc. to EN ISO 13849-1: | 4/e |
SIL CL acc. to IEC/EN 62061: | 3 |
Nominal voltage: | DC |
Thermal current Ith max.: | 8 A |
1- / 2-channel: | 2 |
Application: | Emergency stop, Light barrier, Safety mat, Safety gate, Two-hand |
Cross fault detection:: | Yes |
Connection: | Pluggable screw terminals, Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire |
Safe output contacts, redundant NO contacts: | 2 |
Approvals: | UL |