send message order online
+372 62 28 220 call us for best offer

MULTIFUNCTIONAL SAFETY MODULE UG6970.04PT/61 DC24V (0066321)

send

The multifunctional safety module UG 6970 provides protection of men and machines by enabling and disabling a safety circuit. It is used together with e-stop buttons, safety gates, light curtains with self testing (type 4) to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and productions machines with dangerous closing movements (type III C to EN ISO 13851) and safety mats, edges and tape switches. Simply select 2 out of 6 safety functions on rotary switches - ready. This reduces divers types of safety modules in stock and simplifies your disposition.

Applications

For enable and interrupt a safety circuit in a safe way. It can be used to protect people and machines in applications with e-stop buttons, safety gates, light curtains with selftesting (Type 4) acc. to IEC/EN 61496-1, 2-hand controls for presses as well as other production machinery with dangerous closing action (Type III C to EN ISO 13851) and for safety mats, safety edges and tape switches with a max. switching current of 15 mA

Downloads

Datasheet UG 6970

Technical specifications

Manufacturer: Dold
Series: UG 6970
Type: UG6970.04PT/61 DC24V
Article number: 0066321
Sales Price: € 527,00

Contacts: 2 NO contacts each safety function
Nominal voltage: DC 24 V
Terminal type: Pluggable terminal blocks with cage clamp terminals 2-wire
Approvals and Markings: UL-listed C/US, TÜV, UKCA
Variant: 2 independent, separately adjustable safety functions
Common technical specifications UG 6970
Width: 22,5 mm
Cat. / PL acc. to EN ISO 13849-1: 4/e
SIL CL acc. to IEC/EN 62061: 3
Nominal voltage: DC
Thermal current Ith max.: 8 A
1- / 2-channel: 2
Application: Emergency stop, Light barrier, Safety mat, Safety gate, Two-hand
Cross fault detection:: Yes
Connection: Pluggable screw terminals, Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire
Safe output contacts, redundant NO contacts: 4
Approvals: UL