DOLD EMERGENCY STOP MODULE LG 5928

send

Emergency Stop Module with time delay LG 5928. Ideal for designs according to the new safety standards.

Applications

  • Protection of people and machines
  • Emergency stop circuits on machines, Stop category 1 can be realised
  • Monitoring of safety gates

Downloads

Datasheet LG 5928


MODEL RANGE
Order Code Model Description Sales Price
0062506 LG5928.41/001/61 DC24V 3S EMERGENCY STOP MODULE € 363,00
0061684 LG5928.41/001/61 DC24V 5S EMERGENCY STOP MODULE € 363,00
0062214 LG5928.41/61 DC24V 0,1-1S EMERGENCY STOP MODULE € 363,00
0062880 LG5928.41/61 DC24V 0,3-3S EMERGENCY STOP MODULE € 363,00
0063264 LG5928.41/61 DC24V 0,5-5S EMERGENCY STOP MODULE € 363,00
0061683 LG5928.41/61 DC24V 1-10S EMERGENCY STOP MODULE € 363,00
0062505 LG5928.41/61 DC24V 30-300S EMERGENCY STOP MODULE € 363,00
0062938 LG5928.41/61 DC24V 3-30S EMERGENCY STOP MODULE € 363,00
0065509 LG5928.41/61 DC24V 60-600S EMERGENCY STOP MODULE € 363,00
0065685 LG5928.41/61 DC24V 6-60S EMERGENCY STOP MODULE € 363,00
0065220 LG5928.41PC/61 DC24V 0,1-1S EMERGENCY STOP MODULE € 378,00
0063677 LG5928.41PC/61 DC24V 0,3-3S EMERGENCY STOP MODULE € 378,00
0064413 LG5928.41PC/61 DC24V 1-10S EMERGENCY STOP MODULE € 378,00
0064801 LG5928.41PS/61 DC24V 0,3-3S EMERGENCY STOP MODULE € 372,00
0063263 LG5928.41PS/61 DC24V 0,5-5S EMERGENCY STOP MODULE € 372,00
0065298 LG5928.41PS/61 DC24V 1-10S EMERGENCY STOP MODULE € 372,00
Technical Information and Features

Advantages

  • Compact, flexible and safe
  • Short response time
  • Ideal for designs according to the new safety standards

Features

  • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • Output: 2 NO instantaneous contacts and 1 release delay contact
  • 1- or 2-channel connection
  • Line fault detection at the ON pushbuttons at connection on terminals S33-S34
  • Manual restart with button on S33-S34 or automatic restart with bridge between S13-S34
  • With or without cross fault monitoring in the E-stop loop
  • Indication for released time circuit
  • LED indication for supply, channel 1/2 and release delayed contacts
  • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46228-1/-2/-3
  • As option with pluggable terminal blocks for easy exchange of devices
    - with screw terminals
    - or with cage clamp terminals
  • Width 22.5 mm