DOLD EMERGENCY STOP MODULE BN 5930.48/203
SAFEMASTER Emergency Stop Module BN 5930.48/203 with cross fault detection by connecting 2 different phases, max. 400 V.
Applications
Protection of persons and machines- Emergency-stop circuits on machines
- Monitoring safety gates
Downloads
MODEL RANGE
Order Code | Model | Description | Sales Price | |
---|---|---|---|---|
0043384 | BN5930.48/203 AC110V 50/60HZ/ DC60V | EMERGENCY STOP MODULE | € 502,00 | |
0056657 | BN5930.48/203 AC120V 50/60HZ | EMERGENCY STOP MODULE | € 502,00 | |
0041998 | BN5930.48/203 AC230V 50/60HZ/DC110V | EMERGENCY STOP MODULE | € 502,00 | |
0045693 | BN5930.48/203 AC240V 50/60HZ | EMERGENCY STOP MODULE | € 502,00 |
Technical Information and Features
Advantages
- Can be used for long leads in the e-stop loop. This allows a long distance between e-stop module and the e-stop button.
- Crossfault detection in the e-stop circuit./li>
Features
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 - BN 5930.48/203 with cross fault detection by connecting 2 different phases, max. 400 V,
BN 5930.48/204 with cross fault detection by connecting phase and neutral, max. 230 V - Dual voltage version
- Emergency-stop circuit T12, T22: optionally for AC 110 V / DC 60 V or AC 230 V / DC 110 V
- Output: 3 NO, 1 NC contacts for AC 400 V
- 1-channel or 2-channel circuit
- LED displays for channel 1, 2 and mains
- Feedback circuit X1 - X2 for monitoring external contactors
- Removable terminal strips
- Width 100 mm