Fuji Electric, Signal processing Temperature transmitters

B3 model:
- Input type and range selectable with the internal DIP switches and fine calibration using the front potentiometers
- Define input during order : mV, V, T/C, RTD
- Wide supply voltage range 12-45V DC
- Eliminates noise and prevents ground loops with 2000V AC isolation
- 18 mm larged
- Input configurable two-wire transmitters, DIN rail mounted
- Universal inputs and Input-output isolated : mV, resistance, thermocouple, potentiometer
- HART®, HART® SI and PROFIBUS-PA

Fuji Electric B3HU series component identification and points of caution.

The following are general precautions when using this unit. The safety features and precautions specific to the hazardous locations are explained in “Safe Installation Manual” for each certification.

CONFORMITY WITH EC DIRECTIVES.
- Functional insulation is maintained between the input and output.
- The equipment must be mounted inside a panel.
- The actual installation environments such as panel configurations, connected devices, connected wires, may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conformity.

SAFETY PRECAUTION.
- Before you remove the unit or mount it, turn off the power supply and input signal for safety.

ENVIRONMENT.
- Indoor use
- When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation.
- Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact.
- Environmental (non-hazardous location) temperature must be within -40 to +85°C (-40 to +185°F) with relative humidity within 0 to 95% RH in order to ensure adequate life span and operation.
- Be sure that the ventilation slits are not covered with cables, etc.

WIRING.
- Do not install cables (input and output) close to noise sources (relay drive cable, high frequency line, etc.).
- Do not bind these cables together with those in which noises are present. Do not install them in the same duct.

AND ....
- The unit is designed to function as soon as power is supplied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet.

FUJI ELECTRIC B3HU SERIES COMPONENT IDENTIFICATION AND POINTS OF CAUTION.

FUJI ELECTRIC B3HV SERIES COMPONENT IDENTIFICATION AND POINTS OF CAUTION.

CONFORMITY WITH UL.
- This equipment is suitable for use in a Pollution Degree 2 environment.
- This equipment is to be used with the maximum operating voltage 30Vrms and 42.4Vpeak or 60V DC.
- The equipment must be mounted inside a suitable fire enclosure.
- Operating temperature: -40 to +55°C (-40 to +131°F)
- Altitude up to 2000 meters

CONFORMITY WITH EC DIRECTIVES.
- Functional insulation is maintained between signal input and output.
- The input voltage across the terminals must be 70V or less.
- The equipment must be mounted inside a panel.
- Install lightning surge protectors for those wires connected to remote locations.
- The actual installation environments such as panel configurations, connected devices, connected wires, may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conformity.

SAFETY PRECAUTION. 
- Before you remove the unit or mount it, turn off the power supply and input signal for safety.

ENVIRONMENT. 
- Indoor use
- When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation.
- Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact.
- Environmental temperature must be within -40 to +85°C (-40 to +185°F) with relative humidity within 0 to 95% RH in order to ensure adequate life span and operation.
- Be sure that the ventilation slits are not covered with cables, etc.

WIRING. 
- Do not install cables (power supply, input and output) close to noise sources (relay drive cable, high frequency line, etc.).
- Do not bind these cables together with those in which noises are present. Do not install them in the same duct.

AND ....
- The unit is designed to function as soon as power is supplied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet.

FUJI ELECTRIC B3HV SERIES COMPONENT IDENTIFICATION AND POINTS OF CAUTION

Fuji Electric 2 wire universal temperature transmitter - 27U.

The 27 SC converter is a head-mounted two-wire signal converter.
Fuji Electric 2 wire universal temperature transmitter - 27U.
FEATURES:
- Universal input : mV, thermocouple, RTD and resistance
- Programming via PC Configurator (HART® version for 27HU model)
- User’s temperature table can be used
- ATEX / FM IS
- Suitable for Functional Safety applications up to SIL2